71 research outputs found

    Bridging the Language Barrier in Health Awareness

    Get PDF

    NICE – impact on glaucoma case detection

    Get PDF
    Aim:  To investigate the impact of publication of the National Institute of Clinical Excellence (NICE) guidelines (‘Glaucoma: diagnosis and management of chronic open angle glaucoma and ocular hypertension’) in April 2009, on the referrals for suspect glaucoma to Moorfields Community Eye Clinic (MCEC) at Ealing Hospital. / Methods:  The clinical data from all optometrist initiated referrals for suspect glaucoma and ocular hypertension were scrutinised by a Consultant Ophthalmologist for a 2 month period, 6 months after the publication of the NICE guidance. Each was then categorised into the following groups: glaucoma positive; glaucoma suspect; glaucoma negative; ocular hypertension (OHT) requiring further follow up in clinic; ocular hypertension to be followed up by community optometrist; other. The positive predictive value (PPV) was then calculated and a historical comparison made with previous studies. / Results:  A total of 110 new referrals were assessed during the collection period, which reflects a marked increase in numbers attending. However, there was no increase in absolute numbers of glaucoma and glaucoma suspects identified. The absolute numbers of ocular hypertensive patients rose. The PPV fell to 0.25, which is lower than found in previous studies. / Conclusions:  The rising number of new referrals and the unchanged absolute numbers of glaucoma and glaucoma suspects identified following publication of the NICE guidance, in addition to a lower PPV, makes us question what advantage in improved case detection this represents. Furthermore, is this a cost effective strategy? We believe the next step is to introduce a repeat review, with carefully considered clinical governance of any new scheme

    Evaluation of a new rebound tonometer for self-measurement of intraocular pressure

    Get PDF
    BACKGROUND/AIMS: To compare the accuracy of self-obtained, partner-obtained and trainer-obtained measurements using the handheld Icare Home rebound tonometer with Goldmann applanation tonometry (GAT), and to evaluate the acceptability to subjects of Icare Home measurement. METHODS: 76 subjects were trained to use Icare Home for self-measurement using a standardised protocol. A prespecified checklist was used to assess the ability of a subject to perform self-tonometry. Accuracy of Icare Home self-measurement was compared with GAT using one eye per subject, randomly selected. Bland-Altman difference analysis was used to compare Icare Home and GAT intraocular pressure (IOP) estimates. Acceptability of self-tonometry was evaluated using a questionnaire. RESULTS: 56 subjects (74%, 95% CI 64 to 84) were able to correctly perform self-tonometry. Mean bias (95% limits of agreement) was 0.3 mm Hg (−4.6 to 5.2), 1.1 mm Hg (−3.2 to 5.3) and 1.2 mm Hg (−3.9 to 6.3) for self-assessment, partner-assessment and trainer-assessment, respectively, suggesting underestimation of IOP by Icare Home tonometry. Differences between GAT and Icare Home IOP were greater for central corneal thickness below 500 ”m and above 600 ”m than data points within this range. Acceptability questionnaire responses showed high agreement that the self-pressure device was easy to use (84%), the reading was quick to obtain (88%) and the measurement was comfortable (95%). CONCLUSIONS: Icare Home tonometry can be used for self-measurement by a majority of trained subjects. IOP measurements obtained using Icare Home tonometry by self-assessment and third party-assessment showed slight underestimation compared with GAT

    A national survey of diagnostic tests reported by UK community optometrists for the detection of chronic open angle glaucoma

    Get PDF
    Purpose:  In the UK, the majority of cases of chronic open angle glaucoma are detected by community optometrists following a routine sight test. However, there is potential for variability in case finding strategies used. The aim of this study was to carry out a national web-based survey to determine current diagnostic tests used by optometrists in glaucoma case finding. / Methods:  Optometrists on the Association of Optometrists (AOP) electronic database were invited to participate. The survey was open for 16 weeks between April and July 2008. / Results:  A total of 1875 optometrists were eligible to enter the survey, of which 1264 answered the questions relating to diagnostic equipment. Respondents were asked to indicate their usual method of examining the optic nerve head. Direct ophthalmoscopy only was used by 25% with the majority (62%) using a combination of direct and slit-lamp binocular indirect methods. The vast majority of optometrists (78%) used non-contact tonometry to measure intraocular pressure, with only 16% routinely using a Goldmann or Perkins applanation tonometer. The perimeter most frequently used was either one of the Henson range of instruments (39%) or the Humphrey Field Analyser (22%). A smaller number of optometrists (<5%) had access to more specialised imaging equipment, such as HRT, GDx or OCT. / Conclusions:  The results of the survey demonstrate that UK optometrists are well equipped to carry out case finding for chronic open angle glaucoma, although there is a lack of standardisation with respect to equipment used

    Are Eye Clinics Safe For The Road? An Observational Report

    Get PDF
    We report an observational study, based on the examination of 319 medical records, identifying the proportion of patients whose driving status was documented on the first and subsequent glaucoma clinic visits. We also established the proportion of patients with documented Driving and Vehicle Licencing Agency (DVLA)-related advice when they did not meet driving standards based on their visual acuity and/or visual fields (VF). On presentation, driving status was assessed in 61% (n=195) patients. Of the remaining 124, 44% (n=55) had their driving status documented at a subsequent visit, on an average 8 years later. Of all patients (78%, n=250) whose driving status was assessed at some stage, 42% (n=134) were drivers. Of the 203 patients who were either drivers or whose driving status was unknown, 37% (n=75) were assessed as having a visual acuity or bilateral VF defect that was below the legal limit for driving, 39 of whom were known drivers. Only 13 were advised to inform the DVLA, and only 5 patients were advised to update their spectacles or listed for surgery to improve their vision. We therefore potentially failed to perform our DVLA duty in 76% (n=57) of patients. We have made suggestions for improving the current performance in this respect based on the findings of this study

    Teleglaucoma: ready to go?

    Get PDF
    Telemedicine technologies and services allow today's ophthalmic clinicians to remotely diagnose, manage and monitor several ophthalmic conditions from a distance. But is this the case for glaucomas? There has been a proliferation of telemedicine friendly devices in recent years that improves the capabilities of the clinician in managing glaucomas. The existing instruments still need to align themselves with accepted industry standards. There are successful programmes running in several areas of the world. The safety and efficacy of these programmes needs further exploration. The inability of a single device or test to diagnose glaucomas satisfactorily has also hampered progress in remotely diagnosing these conditions. There is, however, significant potential for telemedicine-friendly devices to remotely monitor the progress of glaucoma and, thereby, reduce some of the workload on an overstretched health service

    Analysis of neonatal clinical trials with twin births

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In neonatal trials of pre-term or low-birth-weight infants, twins may represent 10–20% of the study sample. Mixed-effects models and generalized estimating equations are common approaches for handling correlated continuous or binary data. However, the operating characteristics of these methods for mixes of correlated and independent data are not well established.</p> <p>Methods</p> <p>Simulation studies were conducted to compare mixed-effects models and generalized estimating equations to linear regression for continuous outcomes. Similarly, mixed-effects models and generalized estimating equations were compared to ordinary logistic regression for binary outcomes. The parameter of interest is the treatment effect in two-armed clinical trials. Data from the National Institute of Child Health & Human Development Neonatal Research Network are used for illustration.</p> <p>Results</p> <p>For continuous outcomes, while the coverage never fell below 0.93, and the type I error rate never exceeded 0.07 for any method, overall linear mixed-effects models performed well with respect to median bias, mean squared error, coverage, and median width. For binary outcomes, the coverage never fell below 0.90, and the type I error rate never exceeded 0.07 for any method. In these analyses, when randomization of twins was to the same treatment group or done independently, ordinary logistic regression performed best. When randomization of twins was to opposite treatment arms, a rare method of randomization in this setting, ordinary logistic regression still performed adequately. Overall, generalized linear mixed models showed the poorest coverage values.</p> <p>Conclusion</p> <p>For continuous outcomes, using linear mixed-effects models for analysis is preferred. For binary outcomes, in this setting where the amount of related data is small, but non-negligible, ordinary logistic regression is recommended.</p

    Identifying characteristic features of the retinal and choroidal vasculature in choroideremia using optical coherence tomography angiography

    Get PDF
    PURPOSE: Using optical coherence tomography angiography (OCTA) to investigate the area with flow in the superficial retinal vessel network (SVRN) and choriocapillaris (CC) layer among male subjects with choroideremia (CHM), female carriers, and normal controls to identify vascular changes. PATIENTS AND METHODS: Images of SRVN and CC layer were acquired in 9 affected males, 5 female carriers, and 14 age- and gender-matched controls using the Angiovue software of the RTVue XR Avanti. RESULTS: The mean age was 33 years for affected male CHM patients (median 30 years), 46 years for female carriers (median 53 years), and 39 years for controls (median 38.5). Mean SRVN area±SD in subjects with CHM was 12.93±2.06 mmÂČ, in carrier subjects 15.36±0.60 mmÂČ, and in controls 15.30±1.35 mmÂČ (P<0.01). The mean CC area±SD with flow was 6.97±5.26 mmÂČ in CHM subjects, 21.65±0.17 mmÂČ in carriers and 21.36±0.76 mmÂČ in controls (P<0.01). SRVN and CC area with flow showed a negative correlation in CHM subjects with the age (r=−0.86; P<0.003 and r=−0.77; P<0.01, respectively). CC area with flow had a positive correlation with SRVN (r=0.83, P<0.001). Overall, visual acuity had a negative correlation with SRVN and CC area with flow (r=−0.67, P<0.001 and r=−0.57, P<0.002, respectively). CONCLUSIONS: This is the first study to highlight changes in the SRVN in CHM subjects. OCTA detected a reduced area with flow in both retinal and choroidal circulations, and may be a useful tool for monitoring natural history and disease progression in forthcoming clinical trials
    • 